Ordering information
On-board type
ZUS1R5
ZU
1
S
2
1R5
3
12
4
DC OUTPUT
5
1Series name
2Single output
3Output wattage
4Input voltage
5Output voltage
R
MODEL
MAX OUTPUT WATTAGE[W]
05
ZUS1R50505
1.50
VOLTAGE[V] 5
CURRENT[A] 0.30
ZUS1R50512
1.56
12
0.13
ZUS1R50515
1.50
15
0.10
ZUS1R51205
1.50
5
0.30
ZUS1R51212
1.56
12
0.13
ZUS1R51215
1.50
15
0.10
ZUS1R52405
1.50
5
0.30
ZUS1R52412
1.56
12
0.13
ZUS1R52415
1.50
15
0.10
ZUS1R54805
1.50
5
0.30
ZUS1R54812
1.56
12
0.13
ZUS1R54815
1.50
15
0.10
ZUS1R52415 ZUS1R54805 ZUS1R54812
DC36 - 72
0.088typ 0.043typ 0.045typ
71typ
73typ
73typ
15
5
12
0.10
0.30
0.13
60max 20max 48max
120max 40max 100max
120max 80max 120max
150max 120max 150max
180max 50max 150max
60max 20max 48max
ZUS1R54815
SPECIFICATIONS
ZU/ZT
MODEL
VOLTAGE[V]
*1
CURRENT[A]
INPUT
*1
EFFICIENCY[%]
VOLTAGE[V]
CURRENT[A]
LINE REGULATION[mV]
LOAD REGULATION[mV]
*2
RIPPLE[mVp-p]
OUTPUT
RIPPLE NOISE[mVp-p] *2
TEMPERATURE REGULATION[mV] -20 to +55C
*3
DRIFT[mV]
START-UP TIME[ms]
OUTPUT VOLTAGE ADJUSTMENT RANGE[V]
OUTPUT VOLTAGE SETTING[V]
PROTECTION
OVERCURRENT PROTECTION
CIRCUIT
INPUT-OUTPUT
ISOLATION INPUT-CASE
OUTPUT-CASE
OPERATING TEMP.,HUMID.AND ALTITUDE
STORAGE TEMP.,HUMID.AND ALTITUDE
ENVIRONMENT
VIBRATION
IMPACT
SAFETY
AGENCY APPROVALS
CASE SIZE/WEIGHT
OTHERS
COOLING METHOD
*1
*2
*3
*
ZUS1R50505 ZUS1R50512 ZUS1R50515 ZUS1R51205 ZUS1R51212
DC4.5 - 9
DC9 - 18
0.441typ 0.459typ 0.441typ 0.176typ 0.183typ
68typ
68typ
68typ
71typ
71typ
5
12
15
5
12
0.30
0.13
0.10
0.30
0.13
20max 48max 60max 20max 48max
40max 100max 120max 40max 100max
80max 120max 120max 80max 120max
120max 150max 150max 120max 150max
50max 150max 180max 50max 150max
20max 48max 60max 20max 48max
20max (Minimum input, Io=100%)
ZUS1R51215 ZUS1R52405 ZUS1R52412
DC18 - 36
0.176typ 0.088typ 0.092typ
71typ
71typ
71typ
15
5
12
0.10
0.30
0.13
60max 20max 48max
120max 40max 100max
120max 80max 120max
150max 120max 150max
180max 50max 150max
60max 20max 48max
Fixed
4.85 - 5.25 11.40 - 12.60 14.25 - 15.75 4.85 - 5.25 11.40 - 12.60 14.25 - 15.75 4.85 - 5.25 11.40 - 12.60 14.25 - 15.75 4.85 - 5.25 11.40 - 12.60 14.25 - 15.75
Works over 105% of rating and recovers automatically
AC500V 1minute, Cutoff current = 10mA, DC500V 50MW min (20t15C)
AC500V 1minute, Cutoff current = 10mA, DC500V 50MW min (20t15C)
AC500V 1minute, Cutoff current = 10mA, DC500V 50MW min (20t15C)
-20 to +71C, 20 - 95%RH (Non condensing) (Refer to DERATING CURVE), 3,000m (10,000feet) max
-40 to +85C, 20 - 95%RH (Non condensing), 9,000m (30,000feet) max
10 - 55Hz, 98.0m/s2 (10G), 3minutes period, 60minutes each along X, Y and Z axis
490.3m/s2 (50G), 11ms, once each X, Y and Z axis
UL60950-1, EN60950-1, EN50178, CSA C22.2 No.60950-1 Complies with IEC60950-1
27.5X7X18mm (WXHXD) / 10g max
Convection
Rated input 5V, 12V, 24V or 48V DC Io=100%.
Measured by 20MHz oscilloscope.
The drift is a change at 25C of ambient temperature and 30 minutes - 8 hours after the input voltage applied at rated input/output.
Series/Parallel operation with other model is not possible.
G-92
0.043typ
73typ
15
0.10
60max
120max
120max
150max
180max
60max