AC-DC Power Supplies Open Frame/ Enclosed type
Ordering information
LEP240F
LEP 240
1
2
F
3
-24
4
Recommended EMI/EMC Filter
NAC-06-472
R
High voltage pulse noise type : NAP series
Low leakage current type : NAM series
LEP
*The EMI/EMC Filter is recommended
*to connect with several devices.
MODEL
DC OUTPUT
LEP240F-24
+24V 10(Peak 20)A
LEP240F-36
+36V 6.7(Peak 13.4)A
-O
5
1Series name
2Output wattage
3Universal input
4Output voltage
5Optional *1 *6
G :Low leakage current
R :with Remote ON/OFF
S :with Chassis
SN:with Chassis & cover
T :Vertical terminal block
U :Operating stop voltage
is set at a lower value
Z :with ZT
LEP240F-48
+48V 5(Peak 10)A
SPECIFICATIONS
MODEL
VOLTAGE[V]
CURRENT[A]
ACIN 100V
ACIN 200V
FREQUENCY[Hz]
INPUT
OUTPUT
PROTECTION
CIRCUIT AND
OTHERS
ISOLATION
ENVIRONMENT
SAFETY AND
NOISE
REGULATIONS
OTHERS
ACIN 100V
ACIN 200V
ACIN 100V
POWER FACTOR
ACIN 200V
ACIN 100V
INRUSH CURRENT[A]
ACIN 200V
LEAKAGE CURRENT[mA]
VOLTAGE[V]
CURRENT[A]
*2
WATTAGE[W]
LINE REGULATION[mV]
LOAD REGULATION[mV]
0 to +40C *3
RIPPLE[mVp-p]
-10 - 0C *3
0 to +40C *3
RIPPLE NOISE[mVp-p]
-10 - 0C *3
0 to +40C
TEMPERATURE REGULATION[mV]
-10 to +40C
DRIFT[mV]
*4
START-UP TIME[ms]
HOLD-UP TIME[ms]
OUTPUT VOLTAGE ADJUSTMENT RANGE[V]
OUTPUT VOLTAGE SETTING[V]
OVERCURRENT PROTECTION
OVERVOLTAGE PROTECTION
REMOTE ON/OFF
INPUT-OUTPUT -RC
*5
INPUT-FG
OUTPUT-RC-FG
*5
OUTPUT-RC
*5
OPERATING TEMP.,HUMID.AND ALTITUDE
STORAGE TEMP.,HUMID.AND ALTITUDE
VIBRATION
IMPACT
AGENCY APPROVALS
CONDUCTED NOISE
HARMONIC ATTENUATOR
CASE SIZE/WEIGHT
COOLING METHOD
EFFICIENCY[%]
LEP240F-24
LEP240F-36
LEP240F-48
AC85 - 264 1f or DC 120 - 370
3.3typ (Io=100%)
1.7typ (Io=100%)
50/60 (47 - 63) or DC
83typ (Io=100%)
84typ (Io=100%)
84typ (Io=100%)
86typ (Io=100%)
87typ (Io=100%)
87typ (Io=100%)
0.98typ (Io=100%)
0.93typ (Io=100%)
15typ (Io=100%) (More than 3sec.to re-start)
30typ (Io=100%) (More than 3sec.to re-start)
0.75max (60Hz, According to IEC60950 and DEN-AN)
+24
+36
+48
0 - 10 (Peak 20)
0 - 6.7 (Peak 13.4)
0 - 5 (Peak 10)
240.0 (Peak 480)
241.2 (Peak 482.4)
240.0 (Peak 480)
48max
48max
48max
76max
90max
150max
120max
120max
150max
160max
160max
300max
150max
150max
250max
180max
180max
350max
120max
150max
240max
145max
180max
300max
48max
48max
48max
500max (ACIN 100V, Io=100%)
20typ (ACIN 100V, Io=100%)
21.4 - 26.4
26.4 - 39.6
39.6 - 52.8
23.0 - 25.0
35.0 - 37.0
46.0 - 50.0
Works over 101% of peak current and recovers automatically
Works at 115 - 140% of rating
Option (Refer to Instruction Manual)
AC3,000V 1minute, Cutoff current = 10mA, DC500V 50MW min (At Room Temperature)
AC2,000V 1minute, Cutoff current = 10mA, DC500V 50MW min (At Room Temperature)
AC500V 1minute, Cutoff current = 100mA, DC500V 50MW min (At Room Temperature)
AC100V 1minute, Cutoff current = 100mA, DC100V 10MW min (At Room Temperature)
-10 to +70C, 20 - 90%RH (Non condensing) (Refer to DERATING CURVE), 3,000m (10,000feet) max
-20 to +75C, 20 - 90%RH (Non condensing), 9,000m (30,000feet) max
10 - 55Hz, 19.6m/s2 (2G), 3minutes period, 60minutes each along X, Y and Z axis
196.1m/s2 (20G), 11ms, once each X, Y and Z axis
UL60950-1, C-UL(CSA60950-1), EN60950-1, EN60065, EN50178 Complies with DEN-AN and IEC60950-1 (At only AC input)
Complies with FCC-B, CISPR22-B, EN55022-B, VCCI-B
Complies with IEC61000-3-2 *7
95X45X222mm [3.74X1.77X8.74 inches] (WXHXD) /690g max (with chassis & cover : 1,070g max)
Convection
*1 Specification is changed at option, refer to Instruction Manual 6.
*2 Peak loading for 10sec. And Duty 35% max, refer to Instruction Manual 5. In detail.
*3 This is the value that measured on measuring board with capacitor of 22mF within 150mm
from output terminal.Measured by 20MHz oscilloscope or Ripple-Noise meter (Equivalent to
KEISOKU-GIKEN: RM101).
*4 Drift is the change in DC output for an eight hour period after a half-hour warm-up at 25C,
with the input voltage held constant at the rated input/output.
LEP-6
*5
*6
*7
*
*
*
Applicable when remote control (optional) is added.
Please contact us about safety approvals for the model with option.
Please contact us about class C.
Parallel operation with other model is not possible.
Derating is required when operated with chassis and cover.
A sound may occur from power supply at peak loading.