ZUS1R50505
Ordering information On-board type ZUS1R5 ZU 1 S 2 1R5 3 12 4 DC OUTPUT 5 1Series name 2Single output 3Output wattage 4Input voltage 5Output voltage R MODEL MAX OUTPUT WATTAGE[W] 05 ZUS1R50505 1.50 VOLTAGE[V] 5 CURRENT[A] 0.30 ZUS1R50512 1.56 12 0.13 ZUS1R50515 1.50 15 0.10 ZUS1R51205 1.50 5 0.30 ZUS1R51212 1.56 12 0.13 ZUS1R51215 1.50 15 0.10 ZUS1R52405 1.50 5 0.30 ZUS1R52412 1.56 12 0.13 ZUS1R52415 1.50 15 0.10 ZUS1R54805 1.50 5 0.30 ZUS1R54812 1.56 12 0.13 ZUS1R54815 1.50 15 0.10 ZUS1R52415 ZUS1R54805 ZUS1R54812 DC36 - 72 0.088typ 0.043typ 0.045typ 71typ 73typ 73typ 15 5 12 0.10 0.30 0.13 60max 20max 48max 120max 40max 100max 120max 80max 120max 150max 120max 150max 180max 50max 150max 60max 20max 48max ZUS1R54815 SPECIFICATIONS ZU/ZT MODEL VOLTAGE[V] *1 CURRENT[A] INPUT *1 EFFICIENCY[%] VOLTAGE[V] CURRENT[A] LINE REGULATION[mV] LOAD REGULATION[mV] *2 RIPPLE[mVp-p] OUTPUT RIPPLE NOISE[mVp-p] *2 TEMPERATURE REGULATION[mV] -20 to +55C *3 DRIFT[mV] START-UP TIME[ms] OUTPUT VOLTAGE ADJUSTMENT RANGE[V] OUTPUT VOLTAGE SETTING[V] PROTECTION OVERCURRENT PROTECTION CIRCUIT INPUT-OUTPUT ISOLATION INPUT-CASE OUTPUT-CASE OPERATING TEMP.,HUMID.AND ALTITUDE STORAGE TEMP.,HUMID.AND ALTITUDE ENVIRONMENT VIBRATION IMPACT SAFETY AGENCY APPROVALS CASE SIZE/WEIGHT OTHERS COOLING METHOD *1 *2 *3 * ZUS1R50505 ZUS1R50512 ZUS1R50515 ZUS1R51205 ZUS1R51212 DC4.5 - 9 DC9 - 18 0.441typ 0.459typ 0.441typ 0.176typ 0.183typ 68typ 68typ 68typ 71typ 71typ 5 12 15 5 12 0.30 0.13 0.10 0.30 0.13 20max 48max 60max 20max 48max 40max 100max 120max 40max 100max 80max 120max 120max 80max 120max 120max 150max 150max 120max 150max 50max 150max 180max 50max 150max 20max 48max 60max 20max 48max 20max (Minimum input, Io=100%) ZUS1R51215 ZUS1R52405 ZUS1R52412 DC18 - 36 0.176typ 0.088typ 0.092typ 71typ 71typ 71typ 15 5 12 0.10 0.30 0.13 60max 20max 48max 120max 40max 100max 120max 80max 120max 150max 120max 150max 180max 50max 150max 60max 20max 48max Fixed 4.85 - 5.25 11.40 - 12.60 14.25 - 15.75 4.85 - 5.25 11.40 - 12.60 14.25 - 15.75 4.85 - 5.25 11.40 - 12.60 14.25 - 15.75 4.85 - 5.25 11.40 - 12.60 14.25 - 15.75 Works over 105% of rating and recovers automatically AC500V 1minute, Cutoff current = 10mA, DC500V 50MW min (20t15C) AC500V 1minute, Cutoff current = 10mA, DC500V 50MW min (20t15C) AC500V 1minute, Cutoff current = 10mA, DC500V 50MW min (20t15C) -20 to +71C, 20 - 95%RH (Non condensing) (Refer to DERATING CURVE), 3,000m (10,000feet) max -40 to +85C, 20 - 95%RH (Non condensing), 9,000m (30,000feet) max 10 - 55Hz, 98.0m/s2 (10G), 3minutes period, 60minutes each along X, Y and Z axis 490.3m/s2 (50G), 11ms, once each X, Y and Z axis UL60950-1, EN60950-1, EN50178, CSA C22.2 No.60950-1 Complies with IEC60950-1 27.5X7X18mm (WXHXD) / 10g max Convection Rated input 5V, 12V, 24V or 48V DC Io=100%. Measured by 20MHz oscilloscope. The drift is a change at 25C of ambient temperature and 30 minutes - 8 hours after the input voltage applied at rated input/output. Series/Parallel operation with other model is not possible. G-92 0.043typ 73typ 15 0.10 60max 120max 120max 150max 180max 60max
COSEL
コーセル株式会社
日本
スイッチング電源の製造・販売
弊社からの見積回答メールの返信又はFAXにてお願いします。