Ordering information
AC-DC Power Supplies Enclosed type
PBA150F
PBA/PBW
PBA/PBW
PB
1
A
2
150
3
F
4
Recommended EMI/EMC Filter
NAC-06-472
R
High voltage pulse noise type : NAP series
Low leakage current type : NAM series
*The EMI/EMC Filter is recommended
*to connect with several devices.
-5
5
-O
6
1Series name
2Single output
3Output wattage
4Universal input
5Output voltage
6Optional *5
C :with Coating
G :Low leakage current
(0.15mA max / ACIN 240V)
E :Low leakage current
and EMI class A
(0.5mA max / ACIN 240V)
T :Vertical terminal block
J :Connector type
(Only -12,-15,-24,-36,-48)
R :with Remote ON/OFF
N :with Cover
(Only 24V UL508 is acquired)
N1 :with DIN rail and Cover
V :Output voltage setting
potentiometer externally
Cover is optional
MODEL
MAX OUTPUT WATTAGE[W]
DC OUTPUT
PBA150F-3R3 PBA150F-5
99
150
3.3V 30A
5V 30A
PBA150F-9
150.3
9V 16.7A
PBA150F-12
156
12V 13A
PBA150F-15
150
15V 10A
PBA150F-24
156
24V 6.5A
PBA150F-36
154.8
36V 4.3A
PBA150F-48
158.4
48V 3.3A
SPECIFICATIONS
MODEL
VOLTAGE[V]
CURRENT[A]
ACIN 100V
ACIN 200V
FREQUENCY[Hz]
INPUT
OUTPUT
PROTECTION
CIRCUIT AND
OTHERS
ISOLATION
ENVIRONMENT
SAFETY AND
NOISE
REGULATIONS
OTHERS
ACIN 100V
ACIN 200V
ACIN 100V
(Io=100%)
POWER FACTOR
ACIN 200V
ACIN 100V
INRUSH CURRENT[A]
ACIN 200V
LEAKAGE CURRENT[mA]
VOLTAGE[V]
CURRENT[A]
LINE REGULATION[mV]
LOAD REGULATION[mV]
0 to +50C *1
RIPPLE[mVp-p]
-10 - 0C *1
0 to +50C *1
RIPPLE NOISE[mVp-p]
-10 - 0C *1
0 to +50C
TEMPERATURE REGULATION[mV]
-10 to +50C
DRIFT[mV]
*2
START-UP TIME[ms]
HOLD-UP TIME[ms]
OUTPUT VOLTAGE ADJUSTMENT RANGE[V]
OUTPUT VOLTAGE SETTING[V]
OVERCURRENT PROTECTION
OVERVOLTAGE PROTECTION[V]
OPERATING INDICATION
REMOTE SENSING
REMOTE ON/OFF
INPUT-OUTPUT -RC
*3
INPUT-FG
OUTPUT-RC-FG
*3
OPERATING TEMP.,HUMID.AND ALTITUDE
STORAGE TEMP.,HUMID.AND ALTITUDE
VIBRATION
IMPACT
AGENCY APPROVALS (At only AC input)
CONDUCTED NOISE
HARMONIC ATTENUATOR
CASE SIZE/WEIGHT
COOLING METHOD
EFFICIENCY[%]
PBA150F-3R3 PBA150F-5
PBA150F-9
PBA150F-12
PBA150F-15
PBA150F-24
PBA150F-36
PBA150F-48
AC85 - 264 1f or DC120 - 370 (AC50 or DC70 Please refer to the instruction manual 2.1 Input voltage *4)
1.3typ
2.0typ
0.7typ
1.0typ
50/60 (47 - 63)
80typ
83typ
82typ
83typ
84typ
85typ
85typ
85typ
82typ
86typ
85typ
86typ
87typ
88typ
88typ
88typ
0.98typ
0.99typ
0.87typ
0.93typ
20typ (Io=100%) (At cold start)
40typ (Io=100%) (At cold start)
0.4/0.75max (ACIN 100V/240V 60Hz, Io=100%, According to IEC60950-1,DENAN)
3.3
5
9
12
15
24
36
48
30
30
16.7
13
10
6.5
4.3
3.3
20max
20max
36max
48max
60max
96max
144max
192max
40max
40max
100max
100max
120max
150max
240max
240max
80max
80max
120max
120max
120max
120max
150max
150max
140max
140max
160max
160max
160max
160max
200max
200max
120max
120max
150max
150max
150max
150max
250max
250max
160max
160max
180max
180max
180max
180max
300max
300max
50max
50max
90max
120max
150max
240max
360max
480max
60max
60max
120max
150max
180max
290max
450max
600max
20max
20max
36max
48max
60max
96max
144max
192max
350typ(ACIN 100V, Io=100%)
20typ (ACIN 100V, Io=100%)
2.85 - 3.63
4.00 - 5.50
7.50 - 10.0
10.0 - 13.2
13.2 - 18.0
19.2 - 27.0
28.8 - 39.6
39.0 - 53.0
3.30 - 3.40
5.00 - 5.15
9.00 - 9.36
12.00 - 12.48 15.00 - 15.60 24.00 - 24.96 36.00 - 37.44 48.00 - 49.92
Works over 105% of rated current and recovers automatically
4.00 - 5.25
5.75 - 7.00
11.5 - 14.0
15.0 - 18.0
20.0 - 25.0
30.0 - 37.0
43.0 - 50.0
58.0 - 65.0
LED (Green)
Optional (Only -3R3, -5 Option -K)
Optional (Required external power source)
AC3,000V 1minute, Cutoff current = 10mA, DC500V 50MWmin (At Room Temperature)
AC2,000V 1minute, Cutoff current = 10mA, DC500V 50MWmin (At Room Temperature)
AC500V 1minute, Cutoff current = 100mA, DC500V 50MWmin (At Room Temperature)
-10 to +71C (Required Derating), 20 - 90%RH (Non condensing) 3,000m (10,000feet) max
-20 to +75C, 20 - 90%RH (Non condensing) 9,000m (30,000feet) max
10 - 55Hz, 19.6m/s2 (2G), 3minutes period, 60minutes each along X, Y and Z axis
196.1m/s2 (20G), 11ms, once each X, Y and Z axis
UL60950-1, C-UL(CSA60950-1), EN60950-1, EN50178 Complies with DEN-AN
Complies with FCC Part15 classB, VCCI-B, CISPR22-B, EN55011-B, EN55022-B
Complies with IEC61000-3-2 *6
34X93X168mm [1.34X3.66X6.61 inches] (without terminal block) (WXHXD) / 560g max (with cover : 630g max)
Convection
*1 Measured by 20MHz oscilloscope or Ripple-Noise meter(equivalent to KEISOKU-GIKEN
:RM101).
*2 Drift is the change in DC output for an eight hour period after a half-hour warm-up at 25C.
*3 Applicable when Remote ON/OFF(optional) is added. RC is insulated with input, output and
FG.
*4 Derating is required.
PBA/PBW-14
PBA/PBW-14
*5
*6
*
*
*
Please contact us about safety approvals for the model with option.
Please contact us about class C.
Parallel operation with other model is not possible.
Derating is required when operated with cover.
A sound may occur from power supply at peak loading.